Our Products

High Voltage AC Resonant Mobile Testing System
(HIGHVOLT – GERMANY)

  • Electrical test system from Germany
  • Test accordance with IEC60502-2, IEC 60840, IEC 62067, and IEEE 400
  • Can be testing medium and high voltage
  • Can be testing the cable length up to 18 km.

Electrical & Industrial Tape
(Coretran-China)

  • EPR tape
  • Semi-Conductive tape
  • Filler tape
  • PVC tape
  • LV Connector with resin kit
  • Cable insulation sealing protective pad

Submersible Secondary Connectors
(CONNECTOR MANUFACTURING COMPANY – USA)

  • Multiple seals incorporated into caps and rockets.
  • High quality EPDM rubber.
  • Clear plated for low-contact resistance.
  • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5.
  • Supplied with aluminum set-screws.
  • Includes silicone grease and CO-OX oxide inhibitor.
  • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength.
  • Each unit individually wrapped and labeled for ease of identification and cleanliness.
  • For installation, CMC® recommends the use of a 9″ insulated hex wrench (no tee handles).

IKI-Overhead-Fault Indicator
(KRIES Energietechnik GmbH & Co.KG - Germany)

  • Short-circuit and earth-fault detection in overhead line networks. With secondary sources (e.g. wind energy converters). Display of first and second alarm event without any change of settings. Requirement: automatic recloser

Cable Joint Resin (Global Resins – UK)

  • The PU238 resin system has been specifically developed for encapsulation of electronics, light electrical applications and cable joints. The system is available in a number of formats but the acclaimed twinpack system is the preferred method of supply for the cable joint kit.

Outdoor Terminator (Sudkabel-Germany)

  • Dry and Solid Insulation
  • Insulator of high grade silicone rubber
  • Field control of silicone rubbber already integrated
  • Significant shorter installation times on site compared to outdoor terminations filled with compound
  • Horizontal assembly possible; lifting tools for integration of termination into console available
  • Arbitrary installation position depending on shed alignlent
  • Free of any insulating fluids or gases
  • Non-flammable

DC Generator (Polar Power Inc. – USA)

Primarily used for prime power systems including solar hybrid

  • Designed for weather extremes, especially hurricanes.
  • All aluminum cabinet with stainless hardware, very corrosion resistant.
  • Available in all fuels: propane, natural gas, and diesel.
  • Can operate up to 6 – 12 months without maintenance or inspection.
  • Engineered to provide 15 to 25 year service life with low maintenance.

Very quiet operation.

CSP Circuit Breaker
(P&A Power Products Inc - Korea)

  • The CSP Protection concept is generally applied to Single phase and Three phase transformers up to 400 kVA. The CSP concept is applied to systems where the low voltage of the transformer might be in the range of 400 to 480 volts.

Underground Distribution Cable Accessories (Elastimold - USA)

  • Elbow Connectors for ring main unit and padmount transformer
  • Separable Connectors – 2 ways, 3 ways, 4 ways
  • Cable Joints (12-35 KV)
  • Elbow Surge Arresters
  • Vacuum Switches

DryKeep - USA

  • The insulation system of most power transformers consists of organic materials… Mineral oil, cellulose paper and pressboard. Moisture in the insulation system, along with operating temperature and oxygen in the transformer oil, constitutes the most important transformer ageing mechanism. Maintaining transformer insulation in a properly “dried-out” state to reduce the ageing phenomenon and the risk of failure can be a difficult and costly process, requiring capital intensive equipment and significant transformer outages.

Surge Arresters and Fuse cutout 21 KV ZForce (MacLean Power Systems - USA)

  • ZForce mold-on polymer housing for the ultimate seal against moisture ingress, high strength fiberglass for high fault-withstand design, integrated ground lead disconnect for fast reliable operation, operates in less than 2 second at 1 amp and less than 2 cycles at 1,000 amps